Niloufar
  • Ann Arbor, MI
  • United States
Share

Niloufar's Friends

  • Inês Maria Mira Martinho
  • Peter von Buelow
  • Rudai Shan

Niloufar's Discussions

1. Batch file written to directory: C:\Users... Run failed.

Started this discussion. Last reply by Inês Maria Mira Martinho Jul 24. 33 Replies

Hello,My DIVA components stopped working since yesterday and I'm getting an error saying that the run failed and a batch file is written to a directory.1- My licence is ok and is working fine in the…Continue

Archsim "zones light electric energy" vs Diva "Lighting Energy(LE)"

Started this discussion. Last reply by Timur Dogan Dec 13, 2016. 1 Reply

Hi,For a single zone space, I'm comparing DIVA's LE output (from the annual daylight component) with Archsim's "zones light electrical energy" (an annual analysis with monthly resolution). What is…Continue

adiabatic construction for zone construction (feeding into advanced zone settings)

Started this discussion. Last reply by J. Alstan Jakubiec Nov 16, 2016. 1 Reply

Hi All,I'm trying to set up a list of different materials to feed into a roof structure. I'm only changing the construction material of the roof, and the rest are remaining the same (adiabatic in…Continue

Annual glare analysis to calculate annual DGP

Started this discussion. Last reply by Jon Sargent on Monday. 4 Replies

Hello,I am trying to do an annual glare analysis by defining three series that cover all the months, days and occupied hours of a year. However, it's not working and is outputting only 30 values. Is…Continue

 

Niloufar's Page

DIVA Day 2014

Thanks to everybody for making DIVA Day 2014 happen at Seattle WA!

http://diva4rhino.com/diva-day-2014

 

Comment Wall (1 comment)

At 11:43pm on July 4, 2014, Dalia Hafiz said…

Hi Niloufar, I have a question for you regarding this earlier discussion on the forum: http://diva4rhino.com/forum/topics/illuminance-luminance-ratio?commentId=6465059%3AComment%3A25057

- I didn't get how to use the plane to calculate the illuminance, was it a horizontal surface or a vertical one placed offset from the wall?

-another question, how was the illuminance values measured in the real-case-study?? by this question I mean was the lux/photo-meter placed vertical or horizontal? using a grid?

-Finally what was the relation between the luminance and illuminance values measured or calculated ( for the same surface?? for the whole image??)

Thanks!

Dalia.

You need to be a member of DIVA for Rhino to add comments!

Join DIVA for Rhino

 
 
 

© 2017   Created by jeff niemasz.   Powered by

Badges  |  Report an Issue  |  Terms of Service